Medical Imaging
Group head: Dr. Kevin Wells
The Biomedical Imaging Group within CVSSP is involved in a wide range of biomedical imaging research projects, which encompasses research at all stages of the imaging chain, from the technology of image acquisition, reconstruction and image correction through to statistical image analysis and display. The group comprises academic staff, research fellows, PhD students and MSc students. Biomedical imaging is fundamentally an inter-disciplinary activity, and therefore all our work is undertaken in collaboration with leading clinical / biomedical partners. As a result of this, research staff and students work in close collaboration with practicing clinicians, medical physicists and biomedical scientists at some of the country's leading hospitals and biomedical companies.If you are interested in pursuing PhD opportunities in these or related areas, please email us for further details of these, and other projects currently under development. Full funding is often available for UK nationals with partial funding for EU nationals. Other funding opportunities also exist from time-to-time for suitably qualified candidates.
You can also undertake a 1 year taught MSc in Medical Imaging or MSc in Medical Imaging with research component. Both of these courses involve a professional placement period at a leading hospital or medical imaging company and a summer project undertaken in collaboration with a biomedical industrial or clinical partner.
The following areas of research make up the MIRS:
Imaging Acquisition Methodology Using Novel Detector / Sensor Technology
Image Reconstruction / Correction / Processing
Image Analysis
People in the Biomedical Imaging Group:
Academic staff:
Research Staff:
Research Students:
Former Members:
Dr. Mary Yip
Department of Physics, University of Surrey, UK
Dr. Jorge Cabello
Dr. Daniel Rodriguez
Dr. Mohammed Alnafea
Department of Physics, University of Surrey, UK
Dr. Jorge Cabello
Dr. Daniel Rodriguez
Queen's Medical Centre University Hospital, Nottingham, UK
Dr. John Chiverton
School of Information Technology, Mae Fah Luang University, Thailand
Dr. Sunil Chandra
Department of Radiological Sciences , CAMS, KSU, Riyadh, Saudi Arabia
Dr. Iqbal SaripanDepartment of Computer and
Communication Systems Engineering, Faculty of Engineering, Universiti
Putra Malaysia, Serdang, Malaysia
Dr. Siti Bejo
Universiti Putra Malaysia, Serdang, Malaysia
Dr. Eleni KokkinouInformation Processing Laboratory,
Electrical and Computer Engineering Dept., Aristotle University of
Thessaloniki, Thessaloniki, Greece
Prof. Maria Petrou
Director of the Informatics and Telematics Institute of CERTH, Thessaloniki, Greece
Select publications:
Journal publications:
2011
M.Yip, A. Mackenzie, E. Lewis, D.R. Dance, K.C. Young and K. Wells. Image resampling effects in mammographic image simulation. Physics in Medicine and Biology, 2011; 56(22): N275-N286.
A. A. Abd. Rahni, E. Lewis, M. Guy, B. Goswami and K. Wells. A particle filter approach to respiratory motion estimation in nuclear medicine imaging. IEEE Transactions on Nuclear Science, 2011; 58(5): 2276-2285.
2010
D. Rodriguez Gutierrez, K. Wells, O. Diaz Montesdeoca, A. Moran Santana, I. A. Mendichovszky and I. Gordon . Partial volume effects in dynamic contrast magnetic resonance renal studies. European Journal of Radiology, 2010; 75(2): 221-229
J. Cabello and K. Wells. The spatial resolution of silicon-based electron detectors in Beta-autoradiography. Physics in Medicine and Biology, 2010; 55(6):1677-1699
2009
S.E. Bohndiek, A. Blue, J. Cabello, A.T. Clark, N. Guerrini, P.M. Evans, E.J. Harris, A. Konstantinidis, D. Maneuski, J. Osmond, V. O'Shea, R.D. Speller, R. Turchetta, K. Wells, H. Zin, N.M. Allinson. Characterization and Testing of LAS: A prototype 'Large Area Sensor' with performance characteristics suitable for medical imaging applications. IEEE Transactions on Nuclear Science, 2009; 56(5):2938-2946
N. Allinson et al. The Multidimensional Integrated Intelligent Imaging project (MI-3). Nuclear Instruments and Methods in Physics Research A, 2009; 604(1-2):196-198
2008
J. P. Chiverton and K. Wells. Adaptive partial volume classification of MRI data. Physics in Medicine and Biology, 2008; 53(20):5577-5594
2007
J. Cabello, A. Bailey, I. Kitchen, M. L. Prydderch, A. T. Clark, R. Turchetta and K. Wells. Digital Autoradiography Using Room Temperature CCD and CMOS Imaging Technology. Physics in Medicine and Biology, 2007; 52(16):4993-5011
M. A. Alnafea, K. Wells, N. M. Spyrou and M. Guy. Preliminary Monte Carlo study of coded aperture imaging with a CZT gamma camera system for scintimammography. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Volume 573, Issues 1-2, 1 April 2007, Pages 122-125
J. P. Chiverton, K. Wells, E. Lewis, C. Chen, B. Podda and D. Johnson. Statistical morphological skull stripping of adult and infant MRI data. Computers in Biology and Medicine, 2007; 37(3):342-357
M. I. Saripan, M. Petrou and K. Wells. Design of a wire-mesh collimator for gamma cameras. IEEE Trans Biomed Eng, 2007;54(9):1598-1612
2006
M. Alnafea, K. Wells, N. M. Spyrou, M. I. Saripan, M. Guy and P. Hinton. Preliminary results from a Monte Carlo study of breast tumour imaging with low-energy high-resolution collimator and a modified uniformly-redundant array-coded aperture. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Volume 563, Issue 1, 1 July 2006, Pages 146-149
2003
E. Kokkinou, K. Wells, M. Petrou and A. Bailey. Digital autoradiography imaging using direct irradiation of a CCD between 278-309 K. IEEE Trans Nuclear Science, 2003; 50(5):1702-1707
2011
M.Yip, A. Mackenzie, E. Lewis, D.R. Dance, K.C. Young and K. Wells. Image resampling effects in mammographic image simulation. Physics in Medicine and Biology, 2011; 56(22): N275-N286.
A. A. Abd. Rahni, E. Lewis, M. Guy, B. Goswami and K. Wells. A particle filter approach to respiratory motion estimation in nuclear medicine imaging. IEEE Transactions on Nuclear Science, 2011; 58(5): 2276-2285.
2010
D. Rodriguez Gutierrez, K. Wells, O. Diaz Montesdeoca, A. Moran Santana, I. A. Mendichovszky and I. Gordon . Partial volume effects in dynamic contrast magnetic resonance renal studies. European Journal of Radiology, 2010; 75(2): 221-229
J. Cabello and K. Wells. The spatial resolution of silicon-based electron detectors in Beta-autoradiography. Physics in Medicine and Biology, 2010; 55(6):1677-1699
2009
S.E. Bohndiek, A. Blue, J. Cabello, A.T. Clark, N. Guerrini, P.M. Evans, E.J. Harris, A. Konstantinidis, D. Maneuski, J. Osmond, V. O'Shea, R.D. Speller, R. Turchetta, K. Wells, H. Zin, N.M. Allinson. Characterization and Testing of LAS: A prototype 'Large Area Sensor' with performance characteristics suitable for medical imaging applications. IEEE Transactions on Nuclear Science, 2009; 56(5):2938-2946
N. Allinson et al. The Multidimensional Integrated Intelligent Imaging project (MI-3). Nuclear Instruments and Methods in Physics Research A, 2009; 604(1-2):196-198
2008
J. P. Chiverton and K. Wells. Adaptive partial volume classification of MRI data. Physics in Medicine and Biology, 2008; 53(20):5577-5594
2007
J. Cabello, A. Bailey, I. Kitchen, M. L. Prydderch, A. T. Clark, R. Turchetta and K. Wells. Digital Autoradiography Using Room Temperature CCD and CMOS Imaging Technology. Physics in Medicine and Biology, 2007; 52(16):4993-5011
M. A. Alnafea, K. Wells, N. M. Spyrou and M. Guy. Preliminary Monte Carlo study of coded aperture imaging with a CZT gamma camera system for scintimammography. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Volume 573, Issues 1-2, 1 April 2007, Pages 122-125
J. P. Chiverton, K. Wells, E. Lewis, C. Chen, B. Podda and D. Johnson. Statistical morphological skull stripping of adult and infant MRI data. Computers in Biology and Medicine, 2007; 37(3):342-357
M. I. Saripan, M. Petrou and K. Wells. Design of a wire-mesh collimator for gamma cameras. IEEE Trans Biomed Eng, 2007;54(9):1598-1612
2006
M. Alnafea, K. Wells, N. M. Spyrou, M. I. Saripan, M. Guy and P. Hinton. Preliminary results from a Monte Carlo study of breast tumour imaging with low-energy high-resolution collimator and a modified uniformly-redundant array-coded aperture. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Volume 563, Issue 1, 1 July 2006, Pages 146-149
2003
E. Kokkinou, K. Wells, M. Petrou and A. Bailey. Digital autoradiography imaging using direct irradiation of a CCD between 278-309 K. IEEE Trans Nuclear Science, 2003; 50(5):1702-1707
Conference publications:
2012
O. Diaz, D.R. Dance, K.C. Young, P. Elangovan, P.R. Bakic and K. Wells. A fast scatter field estimator for digital breast tomosynthesis.SPIE Medical Imaging Proceeding, San Diego, California, USA, February 5-9, 2011.
A. Rashidnasab, P. Elangovan, M. Yip, K.C. Young, D.R. Dance, and K. Wells. Realistic simulation of breast mass appearance using random walk.SPIE Medical Imaging Proceeding, San Diego, California, USA, February 5-9, 2011.
A. Rashidnasab, P. Elangovan, M. Yip, K.C. Young, D.R. Dance, and K. Wells. Modelling realistic breast lesions using diffusion limited aggregation. SPIE Medical Imaging Proceeding, San Diego, California, USA, February 5-9, 2011
M. Esposito, J. Newcombe, T Anaxagoras, N.M. Allison and K. Wells. Using a large area CMOS APS for direct chemiluminescence detection in western blotting electrosphoresis. SPIE Medical Imaging Proceeding, San Diego, California, USA, February 5-9, 2011.
A. Konstantinidis, T. Anaxogoras, M. Esposito, N.M. Allison and R.D. Speller. DynAMITE: a prototype large area CMOS APS for breast cancer diagnosis using x-ray diffraction measurements. SPIE Medical Imaging Proceeding, San Diego, California, USA, February 5-9, 2011.
J. Wu, E. Lewis, J. Giles and G. Ferns. An automated multimodal approach to coronary calcium scoring of adaptive hear isolated MSCT images. SPIE Medical Imaging Proceeding, San Diego, California, USA, February 5-9, 2011.
J. Wu, E. Lewis, G. Ferns and J. Giles. A multimodal fully automated coronary calcium scoring system using adaptive hear isolated multislice CT images. SPIE Medical Imaging Proceeding, San Diego, California, USA, February 5-9, 2011.
M. Alnowami, B. Alnwaimi, M. Copland and K. Wells. A quantitative assessment of using the Kinect for Xbox360TM for respiratory surface motion tracking. SPIE Medical Imaging Proceeding, San Diego, California, USA, February 5-9, 2011.
2011
A.A. Abd. Rahni, E. Lewis, M. Guy and K.Wells. Respiratory Motion Estimation in Nuclear Medicine Imaging Using a Kernel Model-Based Particle Filter Framework. IEEE Medical Imaging Conference (MIC), Valencia, Spain, October 23-29, 2011.
J.Jones , E. Lewis, J. Newcombe, A.A. Abd. Rahni, M. Guy, V. Ezhil and K.Wells. Mosaics of polynomial transformations as a patient specific registration to reduce breathing motion artefacts. IEEE Medical Imaging Conference (MIC), Valencia, Spain, October 23-29, 2011.
M.Esposito, J. Newcombe and K.Wells. Western blotting electrophoretic sequencing: First images with a room temperature CMOS detector. IEEE Medical Imaging Conference (MIC), Valencia, Spain, October 23-29, 2011.
M.Esposito, T. Anaxagoras, A. Fant, K. Wells, A. Konstantinidis, R. D. Speller, J. Osmond, P. M. Evans and N. M. Allinson. DynAMITE: A large area sensor for biomedical applications wih biomodal dynamic range and resolution. IEEE Nuclear Sciense Symposium (NSS), Valencia, Spain, October 23-29, 2011.
A. Rashidnasab, M. Yip, K.C. Young and K. Wells. Simulation of the mammographic appearance of breast lesions. European Medical Physics and Engineering Conference (EMPEC), Dublin, Ireland, September 1-3, 2011.
M.Esposito, T. Anaxagoras, A. Fant, K. Wells, A. Konstantinidis, R. D. Speller, J. Osmond, P. M. Evans and N. M. Allinson. DynAMITe: A Wafer Scale Sensor for Biomedical Applications. Position Sensitive Detector Conference (PSD), Aberystwyth, UK, September 2011.
S. Kiani, I. Gordon, I. Mendichovszky, M. Cutajar and K. Wells. Variation in GFR estimates derived from DCE-MRI renography studies in the presence of reduced signal to noise ratio. International Society for Magnetic Resonance in Medicine (ISMRM), Montreal, Canada, May 7-13, 2011
A.A. Abd. Rahni, E. Lewis, M. Guy, B. Goswami and K. Wells. An iterative particle filter approach for respiratory motion estimation in nuclear medicine imaging. SPIE Medical Imaging Proceedings, Orlando, Florida, USA, February 12-17, 2011.
J. Wu, G. Ferns, J. Giles and E. Lewis. A Framework for Automated Coronary Artery Tracking of Low Axial Resolution Multislice CT images. SPIE Medical Imaging Proceedings, Orlando, Florida, USA, February 12-17, 2011.
A. Mackenzie, A. Workman, D.R. Dance, M. Yip, K. Wells and K.C. Young. Validation of a method to convert an image to appear as if acquired using a different digital detector. SPIE Medical Imaging Proceedings, Orlando, Florida, USA, February 12-17, 2011.
2010
M.R. Alnowami, E. Lewis, M. Guy and K. Wells. Inter and Intra Subject Variation of Abdominal vs. Thoracic Respiratory Motion Using Kernel Density Estimation. IEEE Nuclear Science Symposium and Medical Imaging Conf., Knoxville, Tennessee, USA, October 30 - November 6, 2010.
M.R. Alnowami, E. Lewis, M. Guy and K. Wells. Respiratory Motion Modelling and prediction using Probability Density Estimation. IEEE Nuclear Science Symposium and Medical Imaging Conf., Knoxville, Tennessee, USA, October 30 - November 6, 2010.
M.R. Alnowami, E. Lewis, M. Guy and K. Wells. Marker-less Tracking for Respiratory Motion Correction in Nuclear Medicine. IEEE Nuclear Science Symposium and Medical Imaging Conf., Knoxville, Tennessee, USA, October 30 - November 6, 2010.
A.A. Abd. Rahni, E. Lewis, M. Guy, B. Goswami and K. Wells. Performance Evaluation of a Particle Filter Framework for Respiratory Motion Estimation in Nuclear Medicine Imaging. IEEE Nuclear Science Symposium and Medical Imaging Conf., Knoxville, Tennessee, USA, October 30 - November 6, 2010.
J. Wu, G. Ferns, J. Giles and E. Lewis. Automated Coronary Artery Tracking of Low-Axial Resolution Multi Slice CT. IEEE Nuclear Science Symposium and Medical Imaging Conf., Knoxville, Tennessee, USA, October 30 - November 6, 2010.
O. Diaz, M. Yip, J. Cabello, D.R. Dance, K.C. Young and K. Wells. Monte Carlo simulation of scatter field for calculation of contrast of discs in synthetic CDMAM images. International Workshop on Digital Mammography, Girona, Spain, June 16-18, 2010.
M. Yip, A. Mackenzie, F. Zanca, A. Workman, K.C. Young, D.R. Dance, H. Bosmans,E. Lewis and K. Wells. Validation of a simulated dose reduction methodology using digital mammography CDMAM images and mastectomy images. International Workshop on Digital Mammography, Girona, Spain, June 16-18, 2010.
A. Mackenzie, A. Workman, D.R. Dance, M. Yip, K. Wells and K.C. Young. Adapting Clinical Images to Appear with Different Noise and Sharpness to Model a Different Detector. International Workshop on Digital Mammography, Girona, Spain, June 16-18, 2010.
M. Alnowani, E. Lewis, M. Guy and K. Wells . A marker-less observation model for motion correction in nuclear medicine. SPIE Medical Imaging Proceedings, San Diego, California, USA, February 13-18, 2010.
A.A. Abd. Rahni, E. Lewis, M. Guy and K. Wells. Development of a Particle Filter Framework for Respiratory Motion Correction in Nuclear Medicine Imaging. SPIE Medical Imaging Proceedings, San Diego, California, USA, February 13-18, 2010.
2009
J. Jones, E. Lewis, M. Guy and K. Wells. A virtual dissection based registration to model patient-specific respiratory motion. IEEE Medical Imaging Conf., Orlando, Florida, USA, October 25-31, 2009.
J. Wu, E. Lewis, K. Wells, G. Ferns and J. Giles. Automated Coronary Calcium Scoring Using Predictive Active Contour Segmentation. IEEE Medical Imaging Conf., Orlando, Florida, USA, October 25-31, 2009.
K. Wells, B. Goswami, A. Abd Rahni, J. Jones, M. Alnowami, E. Lewis and M. Guy. A flexible approach to motion correction in nuclear medicine. IEEE Medical Imaging Conf., Orlando, Florida, USA, October 25-31, 2009.
J. Cabello and K. Wells. A Monte Carlo Study on the Spatial Resolution with Silicon-based Detectors. IEEE Medical Imaging Conf., Orlando, Florida, USA, October 25-31, 2009.
J. Cabello, A. Metaxas, A. Bailey, I. Kitchen and K. Wells. Elastic Atlas Registration of Beta-Autoradiograms Using Scattered Data Interpolators. IEEE Medical Imaging Conf., Orlando, Florida, USA, October 25-31, 2009.
M. Yip, W. Chukwu, E. Kottis, E. Lewis, J. M. Oduko, O. Gundogdu, K. C. Young and K. Wells. Automated scoring method for the CDMAM phantom. SPIE Medical Imaging Proceedings, Orlando, USA, 2009; 7263: 72631A-72631A-10.
J. Cabello, A. Bailey, I. Kitchen, M. Guy and K. Wells. Segmentation of low contrast-to-noise ratio images applied to functional imaging using adaptive region growing. SPIE Medical Imaging Proceedings, Orlando, USA, 2009; 7259: 725940-725940-12.
J. Cabello, A. Holland, K. Holland, A. Bailey, I. Kitchen and K. Wells. Betacam: A Commercial Approach to Beta- Autoradiography. SPIE Medical Imaging Proceedings, Orlando, USA, 2009; 7258: 72583P-72583P-7.
2008
M.Yip, A. Alsagar, E. Lewis, K. Wells, K.C. Young. Validation of a Digital Mammography Image Simulation Chain with Automated Scoring of CDMAM Images. In proceedings of the International Workshop on Digital Mammography 2008, LNCS 5116, pp409-416.
J. Cabello, A. Bailey, I. Kitchen, R. Turchetta and K. Wells. A Dual Threshold Method to Independently Control Spatial Resolution and Sensitivity in Beta Imaging. IEEE Nucl. Sci. Symp. Medical Imaging Conf., Dresden, Germany, October 19-25, 2008; 1-7
2007
M.Yip, D. Rodriguez, E. Lewis, K. Wells and K.C. Young. A Simulation Framework for Digital Mammography. IEEE Nucl. Sci. Symp. Medical Imaging Conf., Hawaii, USA, October 27-November 3, 2007; 5: 3635-3639
J. Cabello and K. Wells. A Monte Carlo Investigation in to the the Fundamental Limitations of Digital Beta- Autoradiography: Considerations for Detector Design. IEEE Nucl. Sci. Symp. Medical Imaging Conf., Hawaii, USA, October 27-November 3, 2007; 5: 3625-3630
J. Cabello, K. Wells, A. Bailey and I. Kitchen. Semi-Automatic Elastic Registration Applied to a Beta- Autoradiography Brain Atlas. IEEE Nucl. Sci. Symp. Medical Imaging Conf., Hawaii, USA, October 27-November 3, 2007; 6: 4303-4307
J. Cabello, K. Wells, A. Bailey, I. Kitchen, A. Clark, M. Prydderch and R. Turchetta . Digital Autoradiography Imaging Using CMOS Technology: First Tritium Autoradiography with a Back-Thinned CMOS Detector and Comparison of CMOS Imaging Performance with Autoradiography Film. IEEE Nucl. Sci. Symp. Medical Imaging Conf., Hawaii, USA, October 27-November 3, 2007; 5: 3743-3746
D. Rodriguez Gutierrez, O. Diaz Montesdeoca, A. Moran Santana, K. Wells, J. Cabello, I.A. Mendichovsky, I. Gordon. MR- Based Renography as a replacement for radionuclide diagnostic renography studies. IEEE Nucl. Sci. Symp. Medical Imaging Conf., Hawaii, USA, October 27-November 3, 2007; 6: 4556-4563.
2006
D. Rodriguez, B. Jia, J. Chiverton, K. Wells and M. Partridge. Partial Volume correction for Image-generated Arterial Input Functions. IEEE Nucl. Sci. Symp. Medical Imaging Conf., San Diego, USA, October 29-November 4, 2006; 4: 2091-2094
M. A. Alnafea, K. Wells, M. Guy and N. M. Spyrou. Near Field Corrections for Coded Aperture Imaging in Scintimammography. IEEE Nucl. Sci. Symp. Medical Imaging Conf., San Diego, USA, October 29-November 4, 2006; 5: 2948-2953
J. Chiverton, K. Wells and M. Partridge. A Combined Noise Reduction and Partial Volume Estimation Method for Image Quantitation. IEEE Nucl. Sci. Symp. Medical Imaging Conf., San Diego, USA, October 29-November 4, 2006; 6: 3221-3228
H. Kadhem, D. Rodriguez, R. J. Tena, K. Wells, E. Lewis and M. Guy. Ultra Low Dose CT Attenuation Correction Maps for Emission Computed Tomography. IEEE Nucl. Sci. Symp. Medical Imaging Conf., San Diego, USA, October 29-November 4, 2006; 4: 2123-2127
J. Cabello, A. Bailey, I. Kitchen, A. T. Clark, J. P. Crooks, R. Halsall, M. L. Key-Charriere, S. Martin, M. L. Prydderch, R. Turchetta and K. Wells. Digital Autoradiography Using CCD and CMOS Imaging Technology. IEEE Nucl. Sci. Symp. Medical Imaging Conf., San Diego, USA, October 29-November 4, 2006; 4: 2607-2612
D. Rodriguez Gutierrez, O. Diaz Montesdeoca, K. Wells, I. Mendichovszky and I. Gordon. Partial volume correction for MR Renography studies. British Chapter of the International Society for Magnetic Resonance in Medicine (ISMRM) , Guildford, UK, August 23-25, 2006.
2005
K. Wells, A. Tumian, A. Zapros, M. A. Alnafea, M. I. Saripan, M. Guy and P. Hinton. Optimal energy window selection for scintigraphy and emission computed tomography. IEEE Nucl. Sci. Symp. Medical Imaging Conf., Puerto Rico, 2005; 4: 2049-2053
M. I. Saripan, K. Wells, M. Petrou, M. A. Alnafea and M. Guy. Design of a Multi-hole collimator gamma camera model for use in Monte Carlo simulation. Proceeding of the Medical Image Inderstanding and Analysis. 2005; 1: 97:90
2012
O. Diaz, D.R. Dance, K.C. Young, P. Elangovan, P.R. Bakic and K. Wells. A fast scatter field estimator for digital breast tomosynthesis.SPIE Medical Imaging Proceeding, San Diego, California, USA, February 5-9, 2011.
A. Rashidnasab, P. Elangovan, M. Yip, K.C. Young, D.R. Dance, and K. Wells. Realistic simulation of breast mass appearance using random walk.SPIE Medical Imaging Proceeding, San Diego, California, USA, February 5-9, 2011.
A. Rashidnasab, P. Elangovan, M. Yip, K.C. Young, D.R. Dance, and K. Wells. Modelling realistic breast lesions using diffusion limited aggregation. SPIE Medical Imaging Proceeding, San Diego, California, USA, February 5-9, 2011
M. Esposito, J. Newcombe, T Anaxagoras, N.M. Allison and K. Wells. Using a large area CMOS APS for direct chemiluminescence detection in western blotting electrosphoresis. SPIE Medical Imaging Proceeding, San Diego, California, USA, February 5-9, 2011.
A. Konstantinidis, T. Anaxogoras, M. Esposito, N.M. Allison and R.D. Speller. DynAMITE: a prototype large area CMOS APS for breast cancer diagnosis using x-ray diffraction measurements. SPIE Medical Imaging Proceeding, San Diego, California, USA, February 5-9, 2011.
J. Wu, E. Lewis, J. Giles and G. Ferns. An automated multimodal approach to coronary calcium scoring of adaptive hear isolated MSCT images. SPIE Medical Imaging Proceeding, San Diego, California, USA, February 5-9, 2011.
J. Wu, E. Lewis, G. Ferns and J. Giles. A multimodal fully automated coronary calcium scoring system using adaptive hear isolated multislice CT images. SPIE Medical Imaging Proceeding, San Diego, California, USA, February 5-9, 2011.
M. Alnowami, B. Alnwaimi, M. Copland and K. Wells. A quantitative assessment of using the Kinect for Xbox360TM for respiratory surface motion tracking. SPIE Medical Imaging Proceeding, San Diego, California, USA, February 5-9, 2011.
2011
A.A. Abd. Rahni, E. Lewis, M. Guy and K.Wells. Respiratory Motion Estimation in Nuclear Medicine Imaging Using a Kernel Model-Based Particle Filter Framework. IEEE Medical Imaging Conference (MIC), Valencia, Spain, October 23-29, 2011.
J.Jones , E. Lewis, J. Newcombe, A.A. Abd. Rahni, M. Guy, V. Ezhil and K.Wells. Mosaics of polynomial transformations as a patient specific registration to reduce breathing motion artefacts. IEEE Medical Imaging Conference (MIC), Valencia, Spain, October 23-29, 2011.
M.Esposito, J. Newcombe and K.Wells. Western blotting electrophoretic sequencing: First images with a room temperature CMOS detector. IEEE Medical Imaging Conference (MIC), Valencia, Spain, October 23-29, 2011.
M.Esposito, T. Anaxagoras, A. Fant, K. Wells, A. Konstantinidis, R. D. Speller, J. Osmond, P. M. Evans and N. M. Allinson. DynAMITE: A large area sensor for biomedical applications wih biomodal dynamic range and resolution. IEEE Nuclear Sciense Symposium (NSS), Valencia, Spain, October 23-29, 2011.
A. Rashidnasab, M. Yip, K.C. Young and K. Wells. Simulation of the mammographic appearance of breast lesions. European Medical Physics and Engineering Conference (EMPEC), Dublin, Ireland, September 1-3, 2011.
M.Esposito, T. Anaxagoras, A. Fant, K. Wells, A. Konstantinidis, R. D. Speller, J. Osmond, P. M. Evans and N. M. Allinson. DynAMITe: A Wafer Scale Sensor for Biomedical Applications. Position Sensitive Detector Conference (PSD), Aberystwyth, UK, September 2011.
S. Kiani, I. Gordon, I. Mendichovszky, M. Cutajar and K. Wells. Variation in GFR estimates derived from DCE-MRI renography studies in the presence of reduced signal to noise ratio. International Society for Magnetic Resonance in Medicine (ISMRM), Montreal, Canada, May 7-13, 2011
A.A. Abd. Rahni, E. Lewis, M. Guy, B. Goswami and K. Wells. An iterative particle filter approach for respiratory motion estimation in nuclear medicine imaging. SPIE Medical Imaging Proceedings, Orlando, Florida, USA, February 12-17, 2011.
J. Wu, G. Ferns, J. Giles and E. Lewis. A Framework for Automated Coronary Artery Tracking of Low Axial Resolution Multislice CT images. SPIE Medical Imaging Proceedings, Orlando, Florida, USA, February 12-17, 2011.
A. Mackenzie, A. Workman, D.R. Dance, M. Yip, K. Wells and K.C. Young. Validation of a method to convert an image to appear as if acquired using a different digital detector. SPIE Medical Imaging Proceedings, Orlando, Florida, USA, February 12-17, 2011.
2010
M.R. Alnowami, E. Lewis, M. Guy and K. Wells. Inter and Intra Subject Variation of Abdominal vs. Thoracic Respiratory Motion Using Kernel Density Estimation. IEEE Nuclear Science Symposium and Medical Imaging Conf., Knoxville, Tennessee, USA, October 30 - November 6, 2010.
M.R. Alnowami, E. Lewis, M. Guy and K. Wells. Respiratory Motion Modelling and prediction using Probability Density Estimation. IEEE Nuclear Science Symposium and Medical Imaging Conf., Knoxville, Tennessee, USA, October 30 - November 6, 2010.
M.R. Alnowami, E. Lewis, M. Guy and K. Wells. Marker-less Tracking for Respiratory Motion Correction in Nuclear Medicine. IEEE Nuclear Science Symposium and Medical Imaging Conf., Knoxville, Tennessee, USA, October 30 - November 6, 2010.
A.A. Abd. Rahni, E. Lewis, M. Guy, B. Goswami and K. Wells. Performance Evaluation of a Particle Filter Framework for Respiratory Motion Estimation in Nuclear Medicine Imaging. IEEE Nuclear Science Symposium and Medical Imaging Conf., Knoxville, Tennessee, USA, October 30 - November 6, 2010.
J. Wu, G. Ferns, J. Giles and E. Lewis. Automated Coronary Artery Tracking of Low-Axial Resolution Multi Slice CT. IEEE Nuclear Science Symposium and Medical Imaging Conf., Knoxville, Tennessee, USA, October 30 - November 6, 2010.
O. Diaz, M. Yip, J. Cabello, D.R. Dance, K.C. Young and K. Wells. Monte Carlo simulation of scatter field for calculation of contrast of discs in synthetic CDMAM images. International Workshop on Digital Mammography, Girona, Spain, June 16-18, 2010.
M. Yip, A. Mackenzie, F. Zanca, A. Workman, K.C. Young, D.R. Dance, H. Bosmans,E. Lewis and K. Wells. Validation of a simulated dose reduction methodology using digital mammography CDMAM images and mastectomy images. International Workshop on Digital Mammography, Girona, Spain, June 16-18, 2010.
A. Mackenzie, A. Workman, D.R. Dance, M. Yip, K. Wells and K.C. Young. Adapting Clinical Images to Appear with Different Noise and Sharpness to Model a Different Detector. International Workshop on Digital Mammography, Girona, Spain, June 16-18, 2010.
M. Alnowani, E. Lewis, M. Guy and K. Wells . A marker-less observation model for motion correction in nuclear medicine. SPIE Medical Imaging Proceedings, San Diego, California, USA, February 13-18, 2010.
A.A. Abd. Rahni, E. Lewis, M. Guy and K. Wells. Development of a Particle Filter Framework for Respiratory Motion Correction in Nuclear Medicine Imaging. SPIE Medical Imaging Proceedings, San Diego, California, USA, February 13-18, 2010.
2009
J. Jones, E. Lewis, M. Guy and K. Wells. A virtual dissection based registration to model patient-specific respiratory motion. IEEE Medical Imaging Conf., Orlando, Florida, USA, October 25-31, 2009.
J. Wu, E. Lewis, K. Wells, G. Ferns and J. Giles. Automated Coronary Calcium Scoring Using Predictive Active Contour Segmentation. IEEE Medical Imaging Conf., Orlando, Florida, USA, October 25-31, 2009.
K. Wells, B. Goswami, A. Abd Rahni, J. Jones, M. Alnowami, E. Lewis and M. Guy. A flexible approach to motion correction in nuclear medicine. IEEE Medical Imaging Conf., Orlando, Florida, USA, October 25-31, 2009.
J. Cabello and K. Wells. A Monte Carlo Study on the Spatial Resolution with Silicon-based Detectors. IEEE Medical Imaging Conf., Orlando, Florida, USA, October 25-31, 2009.
J. Cabello, A. Metaxas, A. Bailey, I. Kitchen and K. Wells. Elastic Atlas Registration of Beta-Autoradiograms Using Scattered Data Interpolators. IEEE Medical Imaging Conf., Orlando, Florida, USA, October 25-31, 2009.
M. Yip, W. Chukwu, E. Kottis, E. Lewis, J. M. Oduko, O. Gundogdu, K. C. Young and K. Wells. Automated scoring method for the CDMAM phantom. SPIE Medical Imaging Proceedings, Orlando, USA, 2009; 7263: 72631A-72631A-10.
J. Cabello, A. Bailey, I. Kitchen, M. Guy and K. Wells. Segmentation of low contrast-to-noise ratio images applied to functional imaging using adaptive region growing. SPIE Medical Imaging Proceedings, Orlando, USA, 2009; 7259: 725940-725940-12.
J. Cabello, A. Holland, K. Holland, A. Bailey, I. Kitchen and K. Wells. Betacam: A Commercial Approach to Beta- Autoradiography. SPIE Medical Imaging Proceedings, Orlando, USA, 2009; 7258: 72583P-72583P-7.
2008
M.Yip, A. Alsagar, E. Lewis, K. Wells, K.C. Young. Validation of a Digital Mammography Image Simulation Chain with Automated Scoring of CDMAM Images. In proceedings of the International Workshop on Digital Mammography 2008, LNCS 5116, pp409-416.
J. Cabello, A. Bailey, I. Kitchen, R. Turchetta and K. Wells. A Dual Threshold Method to Independently Control Spatial Resolution and Sensitivity in Beta Imaging. IEEE Nucl. Sci. Symp. Medical Imaging Conf., Dresden, Germany, October 19-25, 2008; 1-7
2007
M.Yip, D. Rodriguez, E. Lewis, K. Wells and K.C. Young. A Simulation Framework for Digital Mammography. IEEE Nucl. Sci. Symp. Medical Imaging Conf., Hawaii, USA, October 27-November 3, 2007; 5: 3635-3639
J. Cabello and K. Wells. A Monte Carlo Investigation in to the the Fundamental Limitations of Digital Beta- Autoradiography: Considerations for Detector Design. IEEE Nucl. Sci. Symp. Medical Imaging Conf., Hawaii, USA, October 27-November 3, 2007; 5: 3625-3630
J. Cabello, K. Wells, A. Bailey and I. Kitchen. Semi-Automatic Elastic Registration Applied to a Beta- Autoradiography Brain Atlas. IEEE Nucl. Sci. Symp. Medical Imaging Conf., Hawaii, USA, October 27-November 3, 2007; 6: 4303-4307
J. Cabello, K. Wells, A. Bailey, I. Kitchen, A. Clark, M. Prydderch and R. Turchetta . Digital Autoradiography Imaging Using CMOS Technology: First Tritium Autoradiography with a Back-Thinned CMOS Detector and Comparison of CMOS Imaging Performance with Autoradiography Film. IEEE Nucl. Sci. Symp. Medical Imaging Conf., Hawaii, USA, October 27-November 3, 2007; 5: 3743-3746
D. Rodriguez Gutierrez, O. Diaz Montesdeoca, A. Moran Santana, K. Wells, J. Cabello, I.A. Mendichovsky, I. Gordon. MR- Based Renography as a replacement for radionuclide diagnostic renography studies. IEEE Nucl. Sci. Symp. Medical Imaging Conf., Hawaii, USA, October 27-November 3, 2007; 6: 4556-4563.
2006
D. Rodriguez, B. Jia, J. Chiverton, K. Wells and M. Partridge. Partial Volume correction for Image-generated Arterial Input Functions. IEEE Nucl. Sci. Symp. Medical Imaging Conf., San Diego, USA, October 29-November 4, 2006; 4: 2091-2094
M. A. Alnafea, K. Wells, M. Guy and N. M. Spyrou. Near Field Corrections for Coded Aperture Imaging in Scintimammography. IEEE Nucl. Sci. Symp. Medical Imaging Conf., San Diego, USA, October 29-November 4, 2006; 5: 2948-2953
J. Chiverton, K. Wells and M. Partridge. A Combined Noise Reduction and Partial Volume Estimation Method for Image Quantitation. IEEE Nucl. Sci. Symp. Medical Imaging Conf., San Diego, USA, October 29-November 4, 2006; 6: 3221-3228
H. Kadhem, D. Rodriguez, R. J. Tena, K. Wells, E. Lewis and M. Guy. Ultra Low Dose CT Attenuation Correction Maps for Emission Computed Tomography. IEEE Nucl. Sci. Symp. Medical Imaging Conf., San Diego, USA, October 29-November 4, 2006; 4: 2123-2127
J. Cabello, A. Bailey, I. Kitchen, A. T. Clark, J. P. Crooks, R. Halsall, M. L. Key-Charriere, S. Martin, M. L. Prydderch, R. Turchetta and K. Wells. Digital Autoradiography Using CCD and CMOS Imaging Technology. IEEE Nucl. Sci. Symp. Medical Imaging Conf., San Diego, USA, October 29-November 4, 2006; 4: 2607-2612
D. Rodriguez Gutierrez, O. Diaz Montesdeoca, K. Wells, I. Mendichovszky and I. Gordon. Partial volume correction for MR Renography studies. British Chapter of the International Society for Magnetic Resonance in Medicine (ISMRM) , Guildford, UK, August 23-25, 2006.
2005
K. Wells, A. Tumian, A. Zapros, M. A. Alnafea, M. I. Saripan, M. Guy and P. Hinton. Optimal energy window selection for scintigraphy and emission computed tomography. IEEE Nucl. Sci. Symp. Medical Imaging Conf., Puerto Rico, 2005; 4: 2049-2053
M. I. Saripan, K. Wells, M. Petrou, M. A. Alnafea and M. Guy. Design of a Multi-hole collimator gamma camera model for use in Monte Carlo simulation. Proceeding of the Medical Image Inderstanding and Analysis. 2005; 1: 97:90



